<title>iio: chemical: bme680: add power management</title>
<updated>2024-12-11T19:20:49+00:00</updated>
<author>
<name>Vasileios Amoiridis</name>
<email>vassilisamir@gmail.com</email>
</author>
<published>2024-12-02T19:23:41+00:00</published>
<link rel='alternate' type='text/html' href='https://git.rulkc.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=1e60a6545c14000e9e896c71dc62206f3a6f14b2'/>
<id>urn:sha1:1e60a6545c14000e9e896c71dc62206f3a6f14b2</id>
<content type='text'>
Add runtime power management to the device.

Signed-off-by: Vasileios Amoiridis &lt;vassilisamir@gmail.com&gt;
Link: https://patch.msgid.link/20241202192341.33187-4-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron &lt;Jonathan.Cameron@huawei.com&gt;
</content>
</entry>
<entry>
<title>iio: chemical: bme680: Add support for preheat current</title>
<updated>2024-11-03T20:33:45+00:00</updated>
<author>
<name>Vasileios Amoiridis</name>
<email>vassilisamir@gmail.com</email>
</author>
<published>2024-11-02T13:13:08+00:00</published>
<link rel='alternate' type='text/html' href='https://git.rulkc.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=56686ac80b859c2049cc372f7837470aa71c98cf'/>
<id>urn:sha1:56686ac80b859c2049cc372f7837470aa71c98cf</id>
<content type='text'>
Add functionality to inject a specified amount of current to the heating
plate before the start of the gas measurement to allow the sensor to reach
faster to the requested temperature.

Signed-off-by: Vasileios Amoiridis &lt;vassilisamir@gmail.com&gt;
Link: https://patch.msgid.link/20241102131311.36210-5-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron &lt;Jonathan.Cameron@huawei.com&gt;
</content>
</entry>
<entry>
<title>iio: chemical: bme680: Add triggered buffer support</title>
<updated>2024-11-03T20:33:45+00:00</updated>
<author>
<name>Vasileios Amoiridis</name>
<email>vassilisamir@gmail.com</email>
</author>
<published>2024-11-02T13:13:07+00:00</published>
<link rel='alternate' type='text/html' href='https://git.rulkc.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=80b9f3a80e6e23d91aaca5ece28cd5710d5ad715'/>
<id>urn:sha1:80b9f3a80e6e23d91aaca5ece28cd5710d5ad715</id>
<content type='text'>
Add triggered buffer and soft timestamp support. The available scan mask
enables all the channels of the sensor in order to follow the operation of
the sensor. The sensor basically starts to capture from all channels
as long as it enters into FORCED mode.

The bulk read, reads a total of 15 registers from the sensor, 0x1D..0x2B.
Even though some of those registers are not reported in the register map
of the device, this is how the BME680 Sensor API [1] proposes to do it.
This allows to have one bulk read instead of multiple ones.

Link: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x.c#L1200
Signed-off-by: Vasileios Amoiridis &lt;vassilisamir@gmail.com&gt;
Link: https://patch.msgid.link/20241102131311.36210-4-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron &lt;Jonathan.Cameron@huawei.com&gt;
</content>
</entry>
<entry>
<title>iio: chemical: bme680: refactorize set_mode() mode</title>
<updated>2024-11-03T20:33:45+00:00</updated>
<author>
<name>Vasileios Amoiridis</name>
<email>vassilisamir@gmail.com</email>
</author>
<published>2024-11-02T13:13:05+00:00</published>
<link rel='alternate' type='text/html' href='https://git.rulkc.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=4865ee12c8d82e154f0eec28f2592a1248037ab1'/>
<id>urn:sha1:4865ee12c8d82e154f0eec28f2592a1248037ab1</id>
<content type='text'>
Refactorize the set_mode() function to use an external enum that
describes the possible modes of the BME680 device instead of using
true/false variables for selecting SLEEPING/FORCED mode.

Signed-off-by: Vasileios Amoiridis &lt;vassilisamir@gmail.com&gt;
Link: https://patch.msgid.link/20241102131311.36210-2-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron &lt;Jonathan.Cameron@huawei.com&gt;
</content>
</entry>
<entry>
<title>iio: chemical: bme680: optimize startup time</title>
<updated>2024-11-01T14:54:47+00:00</updated>
<author>
<name>Vasileios Amoiridis</name>
<email>vassilisamir@gmail.com</email>
</author>
<published>2024-10-21T19:53:05+00:00</published>
<link rel='alternate' type='text/html' href='https://git.rulkc.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=6ba3df714723563a62e5068b15305a5670cad08d'/>
<id>urn:sha1:6ba3df714723563a62e5068b15305a5670cad08d</id>
<content type='text'>
According to datasheet's Section 1.1, Table 1, the startup time for the
device is 2ms and not 5ms.

Signed-off-by: Vasileios Amoiridis &lt;vassilisamir@gmail.com&gt;
Link: https://patch.msgid.link/20241021195316.58911-3-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron &lt;Jonathan.Cameron@huawei.com&gt;
</content>
</entry>
<entry>
<title>iio: chemical: bme680: Add missing regmap.h include</title>
<updated>2024-11-01T14:54:46+00:00</updated>
<author>
<name>Vasileios Amoiridis</name>
<email>vassilisamir@gmail.com</email>
</author>
<published>2024-10-21T19:53:04+00:00</published>
<link rel='alternate' type='text/html' href='https://git.rulkc.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=b5055b4b4d98e13f6722c041a3f3fd9e3737942a'/>
<id>urn:sha1:b5055b4b4d98e13f6722c041a3f3fd9e3737942a</id>
<content type='text'>
Add the linux/regmap.h header since the struct regmap_config is used
in this file.

Signed-off-by: Vasileios Amoiridis &lt;vassilisamir@gmail.com&gt;
Link: https://patch.msgid.link/20241021195316.58911-2-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron &lt;Jonathan.Cameron@huawei.com&gt;
</content>
</entry>
<entry>
<title>iio: chemical: bme680: Modify startup procedure</title>
<updated>2024-08-03T09:13:35+00:00</updated>
<author>
<name>Vasileios Amoiridis</name>
<email>vassilisamir@gmail.com</email>
</author>
<published>2024-06-09T23:38:22+00:00</published>
<link rel='alternate' type='text/html' href='https://git.rulkc.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=fe358e57afebc33b083551aed5e0093a7ec6db14'/>
<id>urn:sha1:fe358e57afebc33b083551aed5e0093a7ec6db14</id>
<content type='text'>
Modify the startup procedure to reflect the procedure of the Bosch BME68x
Sensor API. The initial readings and configuration of the sensor need to
happen in the following order:

1) Read calibration data [1,2]
2) Chip general configuration [3]
3) Gas configuration [4]

After the chip configuration it is necessary to ensure that the sensor is
in sleeping mode, in order to apply the gas configuration settings [5].

Also, after the soft reset, it is advised to wait for 5ms [6].

Link: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x.c#L162 # [1]
Link: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/examples/forced_mode/forced_mode.c#L44 # [2]
Link: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/examples/forced_mode/forced_mode.c#L53 # [3]
Link: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/examples/forced_mode/forced_mode.c#L60 # [4]
Link: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x.c#L640 # [5]
Link: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x.c#L294 # [6]
Signed-off-by: Vasileios Amoiridis &lt;vassilisamir@gmail.com&gt;
Link: https://patch.msgid.link/20240609233826.330516-12-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron &lt;Jonathan.Cameron@huawei.com&gt;
</content>
</entry>
<entry>
<title>iio: chemical: bme680: Add read buffers in read/write buffer union</title>
<updated>2024-08-03T09:13:34+00:00</updated>
<author>
<name>Vasileios Amoiridis</name>
<email>vassilisamir@gmail.com</email>
</author>
<published>2024-06-09T23:38:20+00:00</published>
<link rel='alternate' type='text/html' href='https://git.rulkc.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=f2f2e7b1a4522d9dc0883e1baf0dea61544cc12b'/>
<id>urn:sha1:f2f2e7b1a4522d9dc0883e1baf0dea61544cc12b</id>
<content type='text'>
Move the buffers that are used in order to read data from the device in
the union which handles all the device read/write buffers. Also create
defines for the number of bytes that are being read from the device and
don't use magic numbers.

Signed-off-by: Vasileios Amoiridis &lt;vassilisamir@gmail.com&gt;
Link: https://patch.msgid.link/20240609233826.330516-10-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron &lt;Jonathan.Cameron@huawei.com&gt;
</content>
</entry>
<entry>
<title>iio: chemical: bme680: Use bulk reads for calibration data</title>
<updated>2024-08-03T09:13:34+00:00</updated>
<author>
<name>Vasileios Amoiridis</name>
<email>vassilisamir@gmail.com</email>
</author>
<published>2024-06-09T23:38:18+00:00</published>
<link rel='alternate' type='text/html' href='https://git.rulkc.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=a4f765e72e6723718cb8df1da77fe18a5488b552'/>
<id>urn:sha1:a4f765e72e6723718cb8df1da77fe18a5488b552</id>
<content type='text'>
Calibration data are located in contiguous-ish registers inside the chip.
For that reason we can use bulk reads as is done as well in the BME68x
Sensor API [1].

The arrays that are used for reading the data out of the sensor
are located inside DMA safe buffer.

Link: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x.c#L1769 # [1]
Signed-off-by: Vasileios Amoiridis &lt;vassilisamir@gmail.com&gt;
Link: https://patch.msgid.link/20240609233826.330516-8-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron &lt;Jonathan.Cameron@huawei.com&gt;
</content>
</entry>
<entry>
<title>iio: chemical: bme680: Remove duplicate register read</title>
<updated>2024-08-03T09:13:34+00:00</updated>
<author>
<name>Vasileios Amoiridis</name>
<email>vassilisamir@gmail.com</email>
</author>
<published>2024-06-09T23:38:17+00:00</published>
<link rel='alternate' type='text/html' href='https://git.rulkc.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=5a387668972d0172bb4e044a313b0a36a041b149'/>
<id>urn:sha1:5a387668972d0172bb4e044a313b0a36a041b149</id>
<content type='text'>
The LSB of the gas register was read first to check if the following
check was correct and then the MSB+LSB were read together. Simplify this
by reading together the MSB+LSB immediately.

Signed-off-by: Vasileios Amoiridis &lt;vassilisamir@gmail.com&gt;
Link: https://patch.msgid.link/20240609233826.330516-7-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron &lt;Jonathan.Cameron@huawei.com&gt;
</content>